IDS 806 8 Zone Intruder Alarm Panel
IDS 806 8 Zone Intruder Alarm Panel represents advanced security technology engineered by Inhep Digital Security, delivering comprehensive protection for residential and commercial properties. This professional-grade control panel integrates sophisticated zone management capabilities with intuitive user operation, making it an ideal choice for security professionals seeking reliable intrusion detection solutions.
Advanced Control Panel Technology
Multi-Zone Management:
- 8-zone capacity with comprehensive monitoring capabilities
- Individual zone programming for Entry/Exit, Instant, Follower, and Stay configurations
- Real-time zone status indication through LED displays
- Tamper monitoring and supervision for enhanced security integrity
User Interface Design:
- Intuitive keypad operation with clear visual feedback
- 15 programmable user codes including Master, General, Maid’s, and Duress codes
- Audio-visual confirmation for all system operations
- Power-save mode functionality reduces energy consumption
Comprehensive Arming and Security Features
The IDS 806 offers multiple arming modes designed to accommodate various security requirements and operational scenarios.
Flexible Arming Options
- Away Arming: Full perimeter and interior protection for unoccupied premises
- Stay Arming: Selective zone monitoring allowing interior movement while protecting perimeter areas
- Stay Arm and Go: Advanced functionality enabling users to arm interior zones while departing premises
- Quick Arming: Single-button activation for rapid system deployment
Emergency Response Capabilities
- Fire alarm integration with distinctive alarm patterns (1 second on, 1 second off)
- Medical emergency activation with rapid buzzer notification
- Panic alarm functionality for immediate emergency response
- Duress code capability for covert distress signaling
Zone Configuration and Management
Intelligent Zone Programming
The system supports sophisticated zone configuration options enabling customized security coverage:
Zone Types:
- Entry/Exit zones with programmable delay periods
- Instant zones for immediate alarm activation
- Follower zones for pathway protection during entry/exit sequences
- Stay zones for areas requiring access during armed periods
Advanced Zone Features
- Buzz Zones: 30-second warning period before alarm activation to prevent false alarms
- Chime Zones: Audible notification for zone violations during disarmed periods
- Zone Bypassing: Temporary deactivation of specific zones while maintaining system protection
- Alarm Memory: Historical record of zone violations during previous armed periods
Communication and Integration Capabilities
Remote Control Integration
The IDS 806 supports wireless remote transmitter functionality through optional Xwave receiver modules:
- 1, 2, and 4-button remote transmitter options
- Dual protocol support (IDS Xwave and Keeloq)
- Programmable button functions for customized operation
- Learning capability for up to 15 remote transmitters
Professional Installation Features
- TCP/IP and RS485 communication protocols for monitoring station connectivity
- Trouble condition monitoring with detailed diagnostic capabilities
- Battery backup system ensures continued operation during power outages
- Professional programming access for advanced configuration options
System Reliability and Maintenance
Built-in Diagnostics
- Comprehensive trouble condition monitoring including:
- AC mains power failure detection
- Low battery voltage monitoring
- Communication line fault detection
- Wireless zone supervision and tamper detection
- Siren circuit integrity monitoring
Professional Support Infrastructure
- 24-month manufacturer warranty from Inhep Electronics Holdings
- Professional installation requirement ensures optimal system performance
- Helpdesk support available for technical assistance
- CE compliance certification for quality assurance
Implementation Benefits for Security Professionals
Operational Efficiency
Security professionals implementing this control panel typically experience significant improvements in system reliability and user satisfaction. The comprehensive programming options enable customization for diverse property types and security requirements.
Cost-Effectiveness Analysis
- Reduced false alarm incidents through intelligent zone programming
- Comprehensive diagnostic capabilities minimize service call requirements
- Flexible user code management accommodates changing access requirements
- Long-term reliability reduces replacement and maintenance costs
Compliance and Standards
- Professional installation requirement ensures adherence to security industry standards
- Comprehensive audit trail capabilities support regulatory compliance
- Robust construction withstands environmental variations and operational stress
- Telecommunications compliance labeling ensures proper integration with monitoring systems
Technical Specifications and Installation
Power Requirements
- DC 12V, 3A primary power supply
- Integrated battery backup system
- Operating temperature range: 0°C to 45°C
- Operating humidity tolerance: 20% to 80%